§ 162-18. Construction and equipment requirements; distance restriction; fencing.  


Latest version.
  • A. 
    No provision of this article shall mitigate any provision of the Building Code that is applicable to swimming pools.
    B. 
    The construction of any swimming pool (portable or permanent) shall follow the design and safety precautions of good building practice. All pools shall be designed and constructed so as to facilitate emptying and cleaning and shall be maintained and operated in such manner as to be clean and sanitary at all times.
    C. 
    All permanent swimming pools shall be so constructed, developed, installed and maintained as to provide necessary equipment for chlorination and other disinfection and filtration. The filtration system shall have sufficient capacity to complete the recirculation of pool water in 18 hours or less.
    D. 
    Swimming pools will not be located over or within 20 feet horizontally from any septic disposal field or within 10 feet horizontally of a septic tank or D-box. No property will be subdivided if the result will be that a swimming pool will be separated in ownership from an adjoining residence.
    Editor's Note: Amended at time of adoption of Code (see Ch. 1, General Provisions, Art. III).
    E. 
    All private swimming pools now existing or hereafter constructed, installed, established or maintained shall be enclosed with a substantial fence and gate that comply with the minimum requirements listed below:
    (1) 
    There shall be a fence at least four feet in height of such nature and construction so as to reasonably preclude the easy entrance of children to the pool area.
    (2) 
    All gates shall be the self-latching type and equipped with a suitable locking device. Where the entire yard or premises whereon the pool is situated is enclosed with fencing and gates of the above specifications, this may be considered proper enclosure of the pool area.
    (3) 
    An above-the-ground pool having a sidewall height of at least four feet above finished ground level is exempt from the above fencing requirement, provided that access to the pool is by means of a removable or retractable ladder. A retractable ladder shall be equipped with a key-operated locking device which will secure the ladder in the retractable position when not in use.
    (4) 
    An above-the-ground pool of sidewall height less than four feet above finished ground level may be exempt from the above fencing requirements, provided that a suitable strong protective covering is placed over the pool and adequately secured whenever the pool is unattended or not in use; and provided, further, that the above provisions with regard to ladders are also adhered to where applicable.
    (5) 
    Small wading pools which are emptied when not in use are exempt from these fencing requirements.
    (6) 
    No part of said fence shall be nearer than five feet to the pool, except this distance shall not be applicable to the aboveground, prefabricated type of pool which has an integral fence attached. The fence shall be constructed in such a way that no person may gain access to the pool beneath or through the fence.
    F. 
    No electrical switches, outlets or appliances and no electrical wiring not in well-grounded shielding conduit shall be within a 10 foot radius of any point of the pool's edge or surface as measured in any direction. No electrical installation shall be so constructed or located that, in the event that it should collapse or fall, it would fall into the pool. The circulating pumps, motors, lights, filtration equipment and all other electrical equipment used in conjunction with a swimming pool shall be electrically supplied through an underwriter's approved ground fault circuit breaker. Such breaker will be mounted within the main service panel within the building on which Public Service has mounted its meter. Ground fault breakers designed to plug into existing wall receptacles will not be approved for pool use. All electrical equipment other than described above which is within 10 feet of any part of the pool or its deck area that may be wetted by pool activity will be installed as to comply with the National Electrical Code, 1978, and as thereafter adopted by the State of New Jersey.
    G. 
    There shall be no physical connection between a potable water system and a pool. The water supply system for a pool shall be in compliance with the National Standard Plumbing Code, 1978, and as thereafter adopted annually by the State of New Jersey.
    H. 